(315) 451-2316
(800) 766-4242
FAX (315) 451-6507

sonic SAFETY SERVICES, INC.
200 SALINA STREET  ~ Suite 101
LIVERPOOL, NEW YORK   13088

 
PRODUCTS
PREVIOUS PAGE
ADD TO FAVORITES
HOME
CONTACT US (email)

ON-SITE SERVICES

PROGRAM MANAGEMENT

Safety & Health Department 
RESPIRATOR PROGRAM

TESTING

RESPIRATOR FIT TESTS
PULMONARY FUNCTION TESTS
AUDIOMETRIC (HEARING) TESTS
NOISE SURVEYS

CALIBRATION~SERVICE~REPAIR

AUDIOMETERS
SOUND BOOTHS
SPIROMETERS
GAS MONITORS & INSTRUMENTS

TRAINING SERVICES

COURSE LIST
INDUSTRIAL PULMONARY FUNCTION
    CERTIFICATION (NIOSH)

INDUSTRIAL PULMONARY FUNCTION
    REFRESHER

CURRENT COURSE SCHEDULE
CUSTOM ON-SITE SAFETY & HEALTH
    TRAINING
ENROLLMENT
COURSE APPLICATION - FAX ~ MAIL

PRODUCTS

AUDIOMETERS & SUPPLIES
BIO-ACOUSTIC SIMULATOR
SOUND BOOTH
SPIROMETERS & SUPPLIES
PERSONAL GAS MONITORS
    GFG (formerly Dynamation)
    HONEYWELL (formerly Zellweger,
         Lumidor, MDA Scientific, Neotronics)

RESPIRATORY AIR MONITORS
AREA GAS DETECTION
CONFINED SPACE TRIPODS &
    BARRICADES

1-800-SONIC 42

LINKS
CONTACT US (email)
HOME

PERSONAL GAS MONITORS
GFG (formerly Dynamation)

MICRO III Single-Gas Detector

Multi-gas detectorPolytector II G750

Microtector G333 - 4 Gas Detector

G850 Broad Band Sensor

AGM 500 Series Multi-Gas Monitor

CGM II 900 Series Multi-gas Monitor


MICRO III
Single-gas detector

Manufactured by GfG

The MICRO III protects you against toxic gas hazards and oxygen deficiency. This Ex-approved personal detector is extraordinary small and weights only 75g, which make it ideally fit into a shirt-pocket. It operates for 9 months on a single dry cell battery. The casing is designed in protection class IP 56 and is extremely shock and scratch resistant.

The long-life sensors of the MICRO III are user replaceable through pre-calibrated spare sensors. The detector itself does all further adjustments. The MICRO III offers 3 threshold alarms and a battery alarm, thereby ensuring a full personal protection. The loudness of the audible alarm with its changing frequency gets improved by means of a resonance cell. In addition to this, in case of an alarm, the two 360º visible, ultra-bright LEDs are alternately flashing.

  • Smallest pocket-size detector

  • Loud audible alarm and ultra bright alarm lamp

  • Smart sensors, pre-calibrated, easy exchange

  • Replaceable battery or accumulator

  • 1 year maintenance-free

  • Adjustable

Call for price and availability!   1-800-766-4242

TOP OF PAGE







Microtector G333
The smallest 4 - gas detector

Manufactured by GfG

The Microtector G 333, with its weight of only 360g, measures up to 4 different gases at a time. It needs only 3 keys for operation. An integrated data logger stores peak and long-term values. The 3 alarm thresholds for every sensor, calibration, zero point and special functions are adjustable by means of the service menu. In case of a gas hazard the detector gives a clearly recognizable audible and visible alarm. A huge LCD-display shows the measurement value and has further features like zoom, contrast and illumination. A rechargeable metal-hydride accumulator allows for operation of up to 16 hours.
  • 1 to 4 gases are measured at a time
  • Compact and handy
  • Easy handling by clearly assigned keys
  • Weights only 360g
  • 3 alarm thresholds for every gas, plus long-term/short-term, peak/minimum value memory
  • Automatic zero point adjustment
  • Ex-protection: EEx d IIC T4
  • Function test: IBS/PFG-no. 413000498

Call for price and availability!   1-800-766-4242

TOP OF PAGE


Multi-gas detector
Polytector II G750

Manufactured by GfG

The Polytector II G750 is a modular designed gas detector and can be used in all gas endangered areas as a flexible gas measurement and detection unit. With 1 to 6 sensors, the G750 monitors several gas hazards at a time. Extremely simple and therefore safe operation of the detector, together with a robust electronic in a rugged casing, make the G750 a practical detection solution. A large graphic display shows all measurement values at once. The warning system directly indicates if a gas is measured in a dangerously high concentration.
  • 1 to 6 gases are measured and displayed at a time
  • Compact and handy, easy handling, weighs only 26 ounces (750g)
  • 3 alarm thresholds for every gas, plus TWA/STEL, minimum/peak values
  • Automatic zero point adjustment, data logger
  • Infrared sensor for CO2
  • Intelligent "smart sensor system", pre-calibrated sensors, easily replaceable
  • Diffusion plus integrated pump
  • Ex-protection ATEX: ` II 2G EEx ib IIC T5
  • Function tested: IBS/PFG-Nr. 413000598
Microprocessor-technique and state-of-the-art sensor technology make the G750 a specialist for measurement and monitoring of gas hazards.
Up to 6 different explosive or toxic gases and oxygen are continuously measured at a time. The "smart sensor system" allows for an adjustment of the measurement task of the G750 by exchanging the pluggable sensors. This means increased flexibility for the user.
Gas supply is made via diffusion or through a built-in sampling pump with up to 30 m sampling line. Thereby it assures that there are no hazardous gases in rooms, manholes, or drains present, so that it is safe to enter these environments.
The measurement values of the last 12 hours are stored in an optional available data logger. This data can be sent to a PC by means of an interface. Storing these measurement values on a PC allows for cost saving archiving and documentation of these values.
With its first-class accumulator the Polytector can operate for up to 14 hours. The accumulator can even get exchanged in ex-areas. Taking into consideration the numerous features on the G750 each function has been assigned to a specific key, which allows for easy operation. On the graphic display the Polytector shows the gas concentration and user instructions. A zoom function and the illuminated display assures a faultless reading of the display even if the view on the display is restricted through darkness or by wearing protection glasses. The Polytector weighs 26 ounces (750g) when fully equipped with 6 sensors, accumulator and pump. The robust design of the detector and the long life sensors assure safe operations even in harsh conditions.

Call for price and availability!   1-800-766-4242

TOP OF PAGE


AGM 500 Series
Multi-Gas Monitor with AutoCal®

Manufactured by GfG

The AGM is a versatile 2-to-4 gas monitor that comes standard with 02 and combustible sensors. The unit can be configured to best match your gas detection needs by adding up to two additional toxic sensors that include: CO, H2S, DualTox (CO/H2S), Cl2, NO2 and SO2.

Calibration and Maintenance
The AutoCal calibration is true "hands-free" calibration with built-in error protection. The AGM will make all adjustments and inform the user when the calibration is complete. The date and time of the successful calibration will be stored in the memory of the AGM and will be displayed during subsequent turn-on sequences. Error protection will display a warning message and prohibit the calibration of the sensor if incorrect calibration gas is used or if a sensor is defective. The removable sensor cover allows easy access to sensors for simple replacement.

PTO Connector and Accessories
The PTO connecor allows power connections for a MINIPump, HILITE, remote readout accessories and communication for PC interface. The attachable MINIPump allows samples to be drawn from remote locations. A hydrophobic filter prevents liquid from entering the pump and a low flow alarm and display will warn the user of sample line blockage. The HILITE alarm is used for high noise environments. This high decibel alarm will sound and display bright "strobe-like" lights when alarm conditions exist. The Remote Readouts (RA-100 and RA-101) consist of a rugged case which will display readings that duplicate those of the AGM up to a distance of 50 feet. When alam levels exist, the RA will display them and sound a 100db horn. All AGM models are data-logging ready. Once the unit is connected to a computer the information may be downlaoaded to display date, time of samples and the level of each gas. This data can be recalled from the PC by operator, date or instrument serial number.
  • 2 - 4 Gas Monitor
  • AutoCal® Automatic Calibration
  • PTO Connection for Accessories and Data-Logging
  • Calibration Time and Date Stamp
  • Lifetime warranty

Call for price and availability!   1-800-766-4242

TOP OF PAGE


AGM 500 Series
Multi-Gas Monitor with AutoCal®

Manufactured by GfG

The AGM is a versatile 2-to-4 gas monitor that comes standard with 02 and combustible sensors. The unit can be configured to best match your gas detection needs by adding up to two additional toxic sensors that include: CO, H2S, DualTox (CO/H2S), Cl2, NO2 and SO2.

Calibration and Maintenance
The AutoCal calibration is true "hands-free" calibration with built-in error protection. The AGM will make all adjustments and inform the user when the calibration is complete. The date and time of the successful calibration will be stored in the memory of the AGM and will be displayed during subsequent turn-on sequences. Error protection will display a warning message and prohibit the calibration of the sensor if incorrect calibration gas is used or if a sensor is defective. The removable sensor cover allows easy access to sensors for simple replacement.

PTO Connector and Accessories
The PTO connecor allows power connections for a MINIPump, HILITE, remote readout accessories and communication for PC interface. The attachable MINIPump allows samples to be drawn from remote locations. A hydrophobic filter prevents liquid from entering the pump and a low flow alarm and display will warn the user of sample line blockage. The HILITE alarm is used for high noise environments. This high decibel alarm will sound and display bright "strobe-like" lights when alarm conditions exist. The Remote Readouts (RA-100 and RA-101) consist of a rugged case which will display readings that duplicate those of the AGM up to a distance of 50 feet. When alam levels exist, the RA will display them and sound a 100db horn. All AGM models are data-logging ready. Once the unit is connected to a computer the information may be downlaoaded to display date, time of samples and the level of each gas. This data can be recalled from the PC by operator, date or instrument serial number.
  • 2 - 4 Gas Monitor
  • AutoCal® Automatic Calibration
  • PTO Connection for Accessories and Data-Logging
  • Calibration Time and Date Stamp
  • Lifetime warranty

Call for price and availability!   1-800-766-4242

TOP OF PAGE


G850 Broad Band Sensor
New standards in personnel safety

Manufactured by GfG

The G 650 sets new standards in personnel safety. Its advanced concepts make him a truly superior confined space instrument. The G 650 combines features you have not dared to dream of. The detector combines the sensibility of a leak detector with the functionality and flexibility of a multi-gas monitor. Whatever combination of gases you need to monitor, the G 650 will reliably take over the measurement task. By its interchangeable cartridges the change of the measurement task becomes simpler than ever.

Increased safety for confined spaces
With its two gas supply modes (diffusion and internal pump) the G 650 is the ideal warning instrument even before entering confined spaces. Confined spaces can be safely monitored before entering by means of the built-in pump. If the pump is switched on (by sliding up the cartridge grill), the diffusion outlet automatically shuts down to avoid a distortion of the measurement results due to wind. A loud acoustic alarm (99dB) and a 360º visible flashing alarm light (5 LEDs) immediately indicate a gas hazard. For extremely noisy environments the G 650 can also be equipped with an optional vibrating alarm.

Remote monitoring
The new G 650 allows two detectors to be connected together such that the two can communicate with each other. Thereby the receiving detector continuously monitors the transmitting detector. The connection to a second detector allows for safe entry into unknown environments. A second person controls the monitored values through a second detector that is connected by means of a cable. Instead of a second detector you can also connect an external display with extra loud alarm module to make sure that the alarm is not overheard in ultra noisy environments or large areas. This allows a worker to be permanently monitored when entering a confined space. Moreover messages can be sent and received to allow communication between attendant and entrant.

Easy operation
Despite its groundbreaking features the G 650 is very user-friendly and simple to operate: 3 buttons are all you need for operation of the detector. The pump is easily activated by sliding the grill upwards. This immediately shuts down the diffusion outlet without the need for further handling.

Protection from hundreds of gases
Up to 6 gases can simultaneously be monitored - oxygen, combustible gases and vapors (in %LEL/Vol.%), up to 3 toxic gases plus you can equip it with the ToxAlert sensor. And all this with one single instrument. Due to the dual-tox sensor for CO and H2S, which continuously monitors both gases with one sensor and accurately displays the measurement values 6 gases are measured even though only 5 sensors are used.

Protection from the unknown
Electrochemical sensors are standard in virtually all portable confined space monitors because they can identify specific known gases. However, in many environments such as sewers or storage vessels, unknown gases may be present. For protection in these cases, a broad range sensor is essential. The groundbreaking broadband sensor ensures you additional superior protection from hundreds of unknown toxic gases. The combustible sensors in conventional gas monitors will detect most gases or vapors. In many instances, the gas or vapor is more toxic to human health before it reaches combustible levels. Some extremely dangerous gases are not combustible and would therefore never be detected.

Flexibility above all
The G 650 is extremely flexible in its measurement tasks. Through its smart sensor technology the sensors can easily be replaced. The G 650 recognizes the sensor type, measuring gas, detection range, calibration curve, as well as alarm threshold values.

Advanced features
The large display with huge readings allows for easy reading of the measurement values even in dimly lit conditions. By a single push of a button the display, affixed on top of the detector, can be turned by 180º to make sure that you can easily view the readings no matter which side you are looking at the detector. When changing the sensors or replacing the battery pack, the detector is immediately operational again. The battery pack can be easily removed from the detector and connected to the charging unit which only needs 4 hours to recharge it. Thereby down times and maintenance times are minimized. The metal hydride battery pack shows no memory effect and ensures a long lifetime.

Robust design for harsh environments
The rugged and small detector weights only 600 grams (21 oz) and is dust and splash-water proof designed in protection class IP 64. It is designed for extremely tough operations under the most difficult conditions. An additional rubber boot assures that the G 650 is extremely resistant against damages from falling.

Data Logger
The data logger saves low and high peak values, which can be displayed later by means of a serial digital interface on a PC.

Affordable
The G 650 is aggressively priced and replaces not only common multi-gas detectors but also additional leak detectors.

Common gas detectors warn of 4 or 5 gases
The G650 Broad Band Sensor protects from hundreds!
Toxic gases, solvents, fuel mixtures (including kerosene and naphtha)
Refrigerants (e.g. R22, R23, R123, R134a, R143, R152a)

Acetone
Acetone nitrile
Acetylene
Acrylnitrile
Ammonia
Benzene
Hydrogen cyanide
Bromomethane
Butadien 1,3
Butane
Butanol
2-Butanon
Butene
Butyl acetate n
Chlorine
Chlorobenzene
Chloromethane
Hydrogen chloride
Cyclohexane
Cyclopentane
Dichlorobenzene
Dichloroethane
Diethylether
Diflouroethane
Dimethylether
Dioxan 1,4
Ethane
Ethandiol
Ethanol
Ethyl acetate
Ethylamine
Ethylene
Ethylen Oxide
Heptane n
Hexane n
Isobutane
Isobutanol
Isopentane
Isopropanol
Isobutyl acetate
Carbon monoxide
LPG
Methane
Methanol
Methyl acetate
Methylamine
Methylethyketon
Nonane n
Octane n
Pentane n
Propane
Propanol
Propene
Propine
Propyl acetate
Propylene oxide
Sulpher dioxide
Hydrogen sulfide
Nitrogen dioxide
Nitrogen monoxide
Styrene
Tetrahydrofurane
Toluene
Trichloroethane
Hydrogen
Xylene

... and many more

Call for price and availability!   1-800-766-4242

TOP OF PAGE


CGM II 900 Series
Multi-gas Monitor with ToxAlert(tm)

 

Manufactured by GfG

ToxAlert Electrochemical sensors are standard in virtually all portable confined space monitors because they can identify specific known gases. However, in many environments such as sewers or storage vessels, unknown gases may be present.
For protection in these cases, a broad range sensor is essential. The ToxAlert sensor literally protects you from hundreds of toxic gases. Today's CGM remains the only instrument to successfully combine the unique characteristics and benefits of both electrochemical and broadrange MOS sensors.

The New Standard in Safety.
The CGM combines smart sensor technology with advanced electronics for a truly superior confined space instrument. The groundbreaking ToxAlert sensor ensures you superior protection from hundreds of unknown toxic gases, and the AutoCal feature simplifies and reduces the time required for calibration. With these key features and a power take off (PTO) port for data logging, an optional mini-pump, remote alarms and other useful accessories, the CGM provides you the protection and convenience you need.

A Misconception
It is true that the combustible sensor in conventional gas monitors will also detect most of the gases or vapors listed below. But the concentration levels at which these gases are combustible is usually far in excess to the level at which they pose a threat to health. Some extremely dangerous gases such as trichloroethylene are not combustible and would therefore never be detected.

The CGM's broad range ToxAlert protects you from hundreds!
Conventional toxic gas detectors can protect you from only two or three gases.

Acetic Acid
Acetone
Acrylonitrile
Ammonia
Benzene
Butanone (MEK)
Butyl Acetate
Butyl Alcohol
Carbon Monoxide
Carbon Tetrachloride
Chlorobenzene
Cyclo hexene
Dichlorobenzene
Dichloroethylene
Dimethylamine
Diisobutyl Ketone
Ethanolamine
Ethyl Acetate
Ethylamine
Ethanol
Ethyl Chloride
Ethyl Chloride
Ethyl ether
Ethyl Mercaptan
Flourotrichloromethane
Formaldehyde
Heptane
Hexane
Hexone
Hydrogen Chloride
Hydrogen Cyanide
Hydrogen Peroxide
Hydrogen Sulfide
Isoamyl Acetate
Isobutyl Alcohol
Isopropyl Alcohol
Isopropylamile
LPG
Methanol
Methyl Acetate
Methyl Alcohol
Methyl Chloride
Methyl Chlorofoam
Methyllene Chloride
Methyl Ketone
Methyl Mercaptan
Methyl Styrene
Naphthalene
Nitropropane
Nitrotolune
Propyl Alcohol
Styrene
Sulfur Dioxide
Tetrachloroethylene
Toluene
Trichloroethylene
Turpentine
Vinyl Chloride
Xylene
Xylidine
...and dozens more

What does OSHA think about broadrange sensors?
"Where the employer has already identified (atmospheric) hazards, substance-specific sensors are preferable, because they accurately indicate the concentrations of identified air contaminants. By contrast, where the employer has not been able to identify the specific atmospheric hazards present or potentially present in a sewer, broadrange sensors are preferable because they indicate that the hazardous threshold of a class (or classes) of contaminants (i.e. hydrocarbons) in the sewer have been exceeded." -1993 Confined Space Standard: 29CFR1910.146 Appendix E

  • 4 gas monitor plus ToxAlert
  • (protection from hundreds of toxic gases)
  • AutoCal(r) calibration
  • Smart sensor technology
  • PTO connection for accessories
  • and data logging
  • Lifetime warranty

Call for price and availability!   1-800-766-4242

TOP OF PAGE

© 2003-2015 sonic SAFETY SERVICES, Inc.
All rights reserved. All images and text on this website are are the property of Sonic Safety Services, Inc. and/or it's suppliers and partners
and cannot be reproduced without permission

This site Designed and Maintained by WEBFox STUDIOS
PLEASE CONTACT THE WEBMASTER WITH ANY ERRORS OR PROBLEMS

Updated October 1, 2015